Search Results (22043 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-21823 1 Redhat 5 Enterprise Linux, Rhel Aus, Rhel E4s and 2 more 2026-04-15 7.5 High
Hardware logic with insecure de-synchronization in Intel(R) DSA and Intel(R) IAA for some Intel(R) 4th or 5th generation Xeon(R) processors may allow an authorized user to potentially enable escalation of privilege local access
CVE-2024-21853 2026-04-15 4.7 Medium
Improper finite state machines (FSMs) in the hardware logic in some 4th and 5th Generation Intel(R) Xeon(R) Processors may allow an authorized user to potentially enable denial of service via local access.
CVE-2024-21885 1 Redhat 6 Enterprise Linux, Rhel Aus, Rhel E4s and 3 more 2026-04-15 7.8 High
A flaw was found in X.Org server. In the XISendDeviceHierarchyEvent function, it is possible to exceed the allocated array length when certain new device IDs are added to the xXIHierarchyInfo struct. This can trigger a heap buffer overflow condition, which may lead to an application crash or remote code execution in SSH X11 forwarding environments.
CVE-2024-21886 2 Redhat, Xorg 8 Enterprise Linux, Rhel Aus, Rhel E4s and 5 more 2026-04-15 7.8 High
A heap buffer overflow flaw was found in the DisableDevice function in the X.Org server. This issue may lead to an application crash or, in some circumstances, remote code execution in SSH X11 forwarding environments.
CVE-2024-53309 2026-04-15 5.5 Medium
A stack-based buffer overflow vulnerability exists in Effectmatrix Total Video Converter Command Line (TVCC) 2.50 when an overly long string is passed to the "-f" parameter. This can lead to memory corruption, potentially allowing arbitrary code execution or causing a denial of service via specially crafted input.
CVE-2025-29476 2026-04-15 5.5 Medium
Buffer Overflow vulnerability in compress_chunk_fuzzer with oss-fuzz on commit 16450518afddcb3139de627157208e49bfef6987 in c-blosc2 v.2.17.0 and before.
CVE-2024-52799 1 Argoproj 1 Argo-helm 2026-04-15 8.3 High
Argo Workflows Chart is used to set up argo and its needed dependencies through one command. Prior to 0.44.0, the workflow-role has excessive privileges, the worst being create pods/exec, which will allow kubectl exec into any Pod in the same namespace, i.e. arbitrary code execution within those Pods. If a user can be made to run a malicious template, their whole namespace can be compromised. This affects versions of the argo-workflows Chart that use appVersion: 3.4 and above, which no longer need these permissions for the only available Executor, Emissary. It could also affect users below 3.4 depending on their choice of Executor in those versions. This only affects the Helm Chart and not the upstream manifests. This vulnerability is fixed in 0.44.0.
CVE-2024-24972 1 Gallagher 2 Controller 6000, Controller 7000 2026-04-15 6.5 Medium
Buffer Copy without Checking Size of Input (CWE-120) in the Controller 6000 and Controller 7000 diagnostic web interface allows an authorised and authenticated operator to reboot the Controller, causing a Denial of Service. Gallagher recommend the diagnostic web page is not enabled (default is off) unless advised by Gallagher Technical support. This interface is intended only for diagnostic purposes. This issue affects: Controller 6000 and Controller 7000 9.10 prior to vCR9.10.240816a (distributed in 9.10.1530 (MR2)), 9.00 prior to vCR9.00.240816a (distributed in 9.00.2168 (MR4)), 8.90 prior to vCR8.90.240816a (distributed in 8.90.2155 (MR5)), 8.80 prior to vCR8.80.240816b (distributed in 8.80.1938 (MR6)), all versions of 8.70 and prior.
CVE-2025-3710 2026-04-15 9.8 Critical
The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to execute arbitrary code on the device.
CVE-2024-25076 2026-04-15 6.8 Medium
An issue was discovered on Renesas SmartBond DA14691, DA14695, DA14697, and DA14699 devices. The bootrom function responsible for validating the Flash Product Header directly uses a user-controllable size value (Length of Flash Config Section) to control a read from the QSPI device into a fixed sized buffer, resulting in a buffer overflow and execution of arbitrary code.
CVE-2024-25115 2026-04-15 7 High
RedisBloom adds a set of probabilistic data structures to Redis. Starting in version 2.0.0 and prior to version 2.4.7 and 2.6.10, specially crafted `CF.LOADCHUNK` commands may be used by authenticated users to perform heap overflow, which may lead to remote code execution. The problem is fixed in RedisBloom 2.4.7 and 2.6.10.
CVE-2024-25137 2026-04-15 4.3 Medium
In AutomationDirect C-MORE EA9 HMI there is a program that copies a buffer of a size controlled by the user into a limited sized buffer on the stack which may lead to a stack overflow. The result of this stack-based buffer overflow can lead to denial-of-service conditions.
CVE-2025-3711 2026-04-15 9.8 Critical
The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to execute arbitrary code on the device.
CVE-2024-25939 2026-04-15 6 Medium
Mirrored regions with different values in 3rd Generation Intel(R) Xeon(R) Scalable Processors may allow a privileged user to potentially enable denial of service via local access.
CVE-2025-3712 2026-04-15 7.5 High
The LCD KVM over IP Switch CL5708IM has a Heap-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to perform a denial-of-service attack.
CVE-2025-3713 2026-04-15 7.5 High
The LCD KVM over IP Switch CL5708IM has a Heap-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to perform a denial-of-service attack.
CVE-2025-3714 2026-04-15 9.8 Critical
The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to execute arbitrary code on the device.
CVE-2025-37149 1 Hpe 1 Proliant Rl300 Gen11 2026-04-15 6 Medium
A potential out-of-bound reads vulnerability in HPE ProLiant RL300 Gen11 Server's UEFI firmware.
CVE-2025-3755 2026-04-15 9.1 Critical
Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU modules allows a remote unauthenticated attacker to read information in the product, to cause a Denial-of-Service (DoS) condition in MELSOFT connection, or to stop the operation of the CPU module (causing a DoS condtion on the CPU module), by sending specially crafted packets. The product is needed to reset for recovery.
CVE-2024-48457 2026-04-15 7.5 High
An issue in Netis Wifi6 Router NX10 2.0.1.3643 and 2.0.1.3582 and Netis Wifi 11AC Router NC65 3.0.0.3749 and Netis Wifi 11AC Router NC63 3.0.0.3327 and 3.0.0.3503 and Netis Wifi 11AC Router NC21 3.0.0.3800, 3.0.0.3500 and 3.0.0.3329 and Netis Wifi Router MW5360 1.0.1.3442 and 1.0.1.3031 allows a remote attacker to obtain sensitive information via the endpoint /cgi-bin/skk_set.cgi and binary /bin/scripts/start_wifi.sh