| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. |
| RAD SecFlow-2 devices with Hardware 0202, Firmware 4.1.01.63, and U-Boot 2010.12 allow URIs beginning with /.. for Directory Traversal, as demonstrated by reading /etc/shadow. |
| A vulnerability was found in Ruijie EG306MG 3.0(1)B11P309. It has been rated as problematic. This issue affects some unknown processing of the file /etc/strongswan.conf of the component strongSwan. The manipulation of the argument i_dont_care_about_security_and_use_aggressive_mode_psk leads to missing encryption of sensitive data. The attack may be initiated remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The vendor was contacted early about this disclosure but did not respond in any way. |
| phpgt/Dom provides access to modern DOM APIs. Versions of phpgt/Dom prior to 4.1.8 expose the GITHUB_TOKEN in the Dom workflow run artifact. The ci.yml workflow file uses actions/upload-artifact@v4 to upload the build artifact. This artifact is a zip of the current directory, which includes the automatically generated .git/config file containing the run's GITHUB_TOKEN. Seeing as the artifact can be downloaded prior to the end of the workflow, there is a few seconds where an attacker can extract the token from the artifact and use it with the GitHub API to push malicious code or rewrite release commits in your repository. Any downstream user of the repository may be affected, but the token should only be valid for the duration of the workflow run, limiting the time during which exploitation could occur. Version 4.1.8 fixes the issue. |
| A vulnerability classified as problematic was found in FNKvision FNK-GU2 up to 40.1.7. Affected by this vulnerability is an unknown functionality of the file /etc/shadow of the component MD5. The manipulation leads to risky cryptographic algorithm. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. |
| An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. When a new SD card is inserted into the dashcam, the existing password is written onto the SD card in cleartext automatically. An attacker with temporary access to the dashcam can switch the SD card to steal this password. |
| A vulnerability has been found in vLLM AIBrix 0.2.0 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file pkg/plugins/gateway/prefixcacheindexer/hash.go of the component Prefix Caching. The manipulation leads to insufficiently random values. The complexity of an attack is rather high. The exploitation appears to be difficult. Upgrading to version 0.3.0 is able to address this issue. It is recommended to upgrade the affected component. |
| SAP GUI for Windows may allow a highly privileged user on the affected client PC to locally access sensitive information stored in process memory during runtime.This vulnerability has a high impact on confidentiality, with no impact on integrity and availability. |
| Toshiba printers will display the password of the admin user in clear-text and additional passwords when sending 2 specific HTTP requests to the internal API. An attacker stealing the cookie of an admin or abusing a XSS vulnerability can recover this password in clear-text and compromise the printer. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |
| iDS6 DSSPro Digital Signage System 6.2 contains a sensitive information disclosure vulnerability that allows remote attackers to intercept authentication credentials through cleartext cookie transmission. Attackers can exploit the autoSave feature to capture user passwords during man-in-the-middle attacks on HTTP communications. |
| An issue was discovered in the COROS application through 3.8.12 for Android. Bluetooth pairing and bonding is neither initiated nor enforced by the application itself. Also, the watch does not enforce pairing and bonding. As a result, any data transmitted via BLE remains unencrypted, allowing attackers within Bluetooth range to eavesdrop on the communication. Furthermore, even if a user manually initiates pairing and bonding in the Android settings, the application continues to transmit data without requiring the watch to be bonded. This fallback behavior enables attackers to exploit the communication, for example, by conducting an active machine-in-the-middle attack. |
| This vulnerability exists in the Tinxy smart devices due to storage of credentials in plaintext within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the plaintext credentials stored on the vulnerable device. |
| QiHang Media Web Digital Signage 3.0.9 contains a sensitive information disclosure vulnerability that allows remote attackers to intercept user authentication credentials through cleartext cookie transmission. Attackers can perform man-in-the-middle attacks to capture and potentially misuse stored authentication credentials transmitted in an insecure manner. |
| A vulnerability, which was classified as problematic, has been found in FNKvision FNK-GU2 up to 40.1.7. Affected by this issue is some unknown functionality of the file /rom/wpa_supplicant.conf. The manipulation leads to cleartext storage of sensitive information. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. |
| Cleartext Storage of Sensitive Information in Memory vulnerability in ABB MConfig.This issue affects MConfig: through 1.4.9.21. |
| Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GT Designer3 Version1 (GOT2000) all versions and Mitsubishi Electric GT Designer3 Version1 (GOT1000) all versions allows a local unauthenticated attacker to obtain plaintext credentials from the project file for GT Designer3. This could allow the attacker to operate illegally GOT2000 series or GOT1000 series by using the obtained credentials. |
| A vulnerability has been found in Coinomi up to 1.7.6. This issue affects some unknown processing. Such manipulation leads to cleartext transmission of sensitive information. The attack can be launched remotely. This attack is characterized by high complexity. The exploitability is assessed as difficult. The exploit has been disclosed to the public and may be used. The vendor replied with: "(...) there isn't any security implication associated with your findings." |
| A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. |
| Lack of sensitive data encryption in CapillaryScope v2.5.0 of Capillary io, which stores both the proxy credentials and the JWT session token in plain text within different registry keys on the Windows operating system. Any authenticated local user with read access to the registry can extract these sensitive values. |
| This vulnerability exists in the Meon KYC solutions due to transmission of sensitive data in plain text within the response payloads of certain API endpoints. An authenticated remote attacker could exploit this vulnerability by intercepting API response that contains unencrypted sensitive information belonging to other users.
Successful exploitation of this vulnerability could allow remote attacker to impersonate the target user and gain unauthorized access to the user account. |