| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Untrusted search path vulnerability in NFC Port Software Version 5.5.0.6 and earlier (for RC-S310, RC-S320, RC-S330, RC-S370, RC-S380, RC-S380/S), NFC Port Software Version 5.3.6.7 and earlier (for RC-S320, RC-S310/J1C, RC-S310/ED4C), PC/SC Activator for Type B Ver.1.2.1.0 and earlier, SFCard Viewer 2 Ver.2.5.0.0 and earlier, NFC Net Installer Ver.1.1.0.0 and earlier allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| Untrusted search path vulnerability in NFC Port Software remover Ver.1.3.0.1 and earlier allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| Untrusted search path vulnerability in LhaForge Ver.1.6.5 and earlier allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| Adobe Acrobat Reader versions 11.0.19 and earlier, 15.006.30280 and earlier, 15.023.20070 and earlier have an insecure library loading (DLL hijacking) vulnerability in the OCR plugin. |
| Adobe Acrobat Reader versions 11.0.19 and earlier, 15.006.30280 and earlier, 15.023.20070 and earlier have an insecure library loading (DLL hijacking) vulnerability in a DLL related to remote logging. |
| Adobe Digital Editions versions 4.5.4 and earlier contain an insecure library loading vulnerability. The vulnerability is due to unsafe library loading of editor control library functions in the installer plugin. A successful exploitation could lead to arbitrary code execution. |
| Adobe Digital Editions versions 4.5.4 and earlier contain an insecure library loading vulnerability. The vulnerability is due to unsafe library loading of browser related library extensions in the installer plugin. A successful exploitation could lead to arbitrary code execution. |
| Code injection vulnerability in Trend Micro Maximum Security 11.0 (and earlier), Internet Security 11.0 (and earlier), and Antivirus+ Security 11.0 (and earlier) allows a local attacker to bypass a self-protection mechanism, inject arbitrary code, and take full control of any Trend Micro process via a "DoubleAgent" attack. One perspective on this issue is that (1) these products do not use the Protected Processes feature, and therefore an attacker can enter an arbitrary Application Verifier Provider DLL under Image File Execution Options in the registry; (2) the self-protection mechanism is intended to block all local processes (regardless of privileges) from modifying Image File Execution Options for these products; and (3) this mechanism can be bypassed by an attacker who temporarily renames Image File Execution Options during the attack. |
| Code injection vulnerability in AVG Ultimate 17.1 (and earlier), AVG Internet Security 17.1 (and earlier), and AVG AntiVirus FREE 17.1 (and earlier) allows a local attacker to bypass a self-protection mechanism, inject arbitrary code, and take full control of any AVG process via a "DoubleAgent" attack. One perspective on this issue is that (1) these products do not use the Protected Processes feature, and therefore an attacker can enter an arbitrary Application Verifier Provider DLL under Image File Execution Options in the registry; (2) the self-protection mechanism is intended to block all local processes (regardless of privileges) from modifying Image File Execution Options for these products; and (3) this mechanism can be bypassed by an attacker who temporarily renames Image File Execution Options during the attack. |
| Symantec VIP Access for Desktop prior to 2.2.4 can be susceptible to a DLL Pre-Loading vulnerability. These types of issues occur when an application looks to call a DLL for execution and an attacker provides a malicious DLL to use instead. Depending on how the application is configured, the application will generally follow a specific search path to locate the DLL. The exploitation of the vulnerability manifests as a simple file write (or potentially an over-write) which results in a foreign executable running under the context of the application. |
| Code injection vulnerability in Avira Total Security Suite 15.0 (and earlier), Optimization Suite 15.0 (and earlier), Internet Security Suite 15.0 (and earlier), and Free Security Suite 15.0 (and earlier) allows a local attacker to bypass a self-protection mechanism, inject arbitrary code, and take full control of any Avira process via a "DoubleAgent" attack. One perspective on this issue is that (1) these products do not use the Protected Processes feature, and therefore an attacker can enter an arbitrary Application Verifier Provider DLL under Image File Execution Options in the registry; (2) the self-protection mechanism is intended to block all local processes (regardless of privileges) from modifying Image File Execution Options for these products; and (3) this mechanism can be bypassed by an attacker who temporarily renames Image File Execution Options during the attack. |
| In Adam Kropelin adk0212 APC UPS Daemon through 3.14.14, the default installation of APCUPSD allows a local authenticated, but unprivileged, user to run arbitrary code with elevated privileges by replacing the service executable apcupsd.exe with a malicious executable that will run with SYSTEM privileges at startup. This occurs because of "RW NT AUTHORITY\Authenticated Users" permissions for %SYSTEMDRIVE%\apcupsd\bin\apcupsd.exe. |
| A DLL Hijack issue was discovered in Rockwell Automation Connected Components Workbench (CCW). The following versions are affected: Connected Components Workbench - Developer Edition, v9.01.00 and earlier: 9328-CCWDEVENE, 9328-CCWDEVZHE, 9328-CCWDEVFRE, 9328-CCWDEVITE, 9328-CCWDEVDEE, 9328-CCWDEVESE, and 9328-CCWDEVPTE; and Connected Components Workbench - Free Standard Edition (All Supported Languages), v9.01.00 and earlier. Certain DLLs included with versions of CCW software can be potentially hijacked to allow an attacker to gain rights to a victim's affected personal computer. Such access rights can be at the same or potentially higher level of privileges as the compromised user account, including and up to computer administrator privileges. |
| An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to Version 3.02.01. An uncontrolled search path element (DLL Hijacking) vulnerability has been identified. Exploitation of this vulnerability could give an attacker access to the system with the same level of privilege as the application that utilizes the malicious DLL. |
| An Uncontrolled Search Path Element issue was discovered in AzeoTech DAQFactory versions prior to 17.1. An uncontrolled search path element vulnerability has been identified, which may execute malicious DLL files that have been placed within the search path. |
| An Uncontrolled Search Path Element issue was discovered in Trihedral VTScada 11.3.03 and prior. The program will execute specially crafted malicious dll files placed on the target machine. |
| A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path. |
| In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application. |
| An Uncontrolled Search Path or Element issue was discovered in i-SENS SmartLog Diabetes Management Software, Version 2.4.0 and prior versions. An uncontrolled search path element vulnerability has been identified which could be exploited by placing a specially crafted DLL file in the search path. If the malicious DLL is loaded prior to the valid DLL, an attacker could execute arbitrary code on the system. This vulnerability does not affect the connected blood glucose monitor and would not impact delivery of therapy to the patient. |
| An Uncontrolled Search Path Element issue was discovered in BLF-Tech LLC VisualView HMI Version 9.9.14.0 and prior. The uncontrolled search path element vulnerability has been identified, which may allow an attacker to run a malicious DLL file within the search path resulting in execution of arbitrary code. |