| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Trilium Notes is an open-source, cross-platform hierarchical note taking application with focus on building large personal knowledge bases. In versions below 0.97.0, a brute-force protection bypass in the initial sync seed retrieval endpoint allows unauthenticated attackers to guess the login password without triggering rate limiting. Trilium is a single-user app without a username requirement, and brute-force protection bypass makes exploitation much more feasible. Multiple features provided by Trilium (e.g. MFA, share notes, custom request handler) indicate that Trilium can be exposed to the internet. This is fixed in version 0.97.0. |
| Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 in order to allow
management operations on the device such as firmware upgrades and device
reboot requiring an authentication. A wrong management of login
failures of the service allows a denial-of-service attack, leaving the telnet service
into an unreachable state. |
| A vulnerability was found in Tenda TDSEE App up to 1.7.12. It has been declared as problematic. Affected by this vulnerability is an unknown functionality of the file /app/ConfirmSmsCode of the component Password Reset Confirmation Code Handler. The manipulation leads to improper restriction of excessive authentication attempts. The attack can be launched remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version 1.7.15 is able to address this issue. It is recommended to upgrade the affected component. |
| A vulnerability was found in Papendorf SOL Connect Center 3.3.0.0 and classified as problematic. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was found in eGauge EG3000 Energy Monitor 3.6.3. It has been classified as problematic. This affects an unknown part of the component Setting Handler. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Reolink Video Doorbell WiFi DB_566128M5MP_W allows root shell access through an unsecured UART/serial console. An attacker with physical access can connect to the exposed interface and execute arbitrary commands with root privileges. NOTE: this is disputed by the Supplier because of "certain restrictions on users privately connecting serial port cables" and because "the root user has a password and it meets the requirements of password security complexity." |
| Akka.NET is a .NET port of the Akka project from the Scala / Java community. In all versions of Akka.Remote from v1.2.0 to v1.5.51, TLS could be enabled via our `akka.remote.dot-netty.tcp` transport and this would correctly enforce private key validation on the server-side of inbound connections. Akka.Remote, however, never asked the outbound-connecting client to present ITS certificate - therefore it's possible for untrusted parties to connect to a private key'd Akka.NET cluster and begin communicating with it without any certificate. The issue here is that for certificate-based authentication to work properly, ensuring that all members of the Akka.Remote network are secured with the same private key, Akka.Remote needed to implement mutual TLS. This was not the case before Akka.NET v1.5.52. Those who run Akka.NET inside a private network that they fully control or who were never using TLS in the first place are now affected by the bug. However, those who use TLS to secure their networks must upgrade to Akka.NET V1.5.52 or later. One patch forces "fail fast" semantics if TLS is enabled but the private key is missing or invalid. Previous versions would only check that once connection attempts occurred. The second patch, a critical fix, enforces mutual TLS (mTLS) by default, so both parties must be keyed using the same certificate. As a workaround, avoid exposing the application publicly to avoid the vulnerability having a practical impact on one's application. However, upgrading to version 1.5.52 is still recommended by the maintainers. |
| Python Social Auth is a social authentication/registration mechanism. In versions prior to 5.6.0, upon authentication, the user could be associated by e-mail even if the `associate_by_email` pipeline was not included. This could lead to account compromise when a third-party authentication service does not validate provided e-mail addresses or doesn't require unique e-mail addresses. Version 5.6.0 contains a patch. As a workaround, review the authentication service policy on e-mail addresses; many will not allow exploiting this vulnerability. |
| The Brightpick Internal Logic Control web interface is accessible
without requiring user authentication. An unauthorized user could
exploit this interface to manipulate robot control functions, including
initiating or halting runners, assigning jobs, clearing stations, and
deploying storage totes. |
| EPSON WebConfig and Epson Web Control for SEIKO EPSON Projector Products do not restrict excessive authentication attempts. An administrative user's password may be identified through a brute force attack. |
| In WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) due to lack of authentication in the configuration change module in the adm.cgi endpoint, the unauthenticated attacker can execute commands including backup creation, device restart and resetting the device to factory settings.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) is vulnerable to Broken Access Control in initial configuration wizard.cgi endpoint. Malicious attacker can change admin panel password without authorization. The vulnerability can also be exploited after the initial configuration has been set.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to read or write the device values of the product and stop the operation of the programs, since MODBUS/TCP in the products does not have authentication features. |
| Missing Authentication for Critical Function, Improper Access Control vulnerability in Dinosoft Business Solutions Dinosoft ERP allows Accessing Functionality Not Properly Constrained by ACLs.This issue affects Dinosoft ERP: from < 3.0.1 through 11022026.
NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| A code execution security issue exists in the affected product. An attacker with physical access could abuse the maintenance menu of the controller with a crafted payload. The security issue can result in arbitrary code execution. |
| Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects .
All firmware versions with the Serial Number from 2000 to 5166 |
| An unauthenticated remote attacker could potentially disrupt operations by switching between multiple configuration presets via HTTP. |
| Chisel is a fast TCP/UDP tunnel, transported over HTTP, secured via SSH. The Chisel server doesn't ever read the documented `AUTH` environment variable used to set credentials, which allows any unauthenticated user to connect, even if credentials were set. Anyone running the Chisel server that is using the `AUTH` environment variable to specify credentials to authenticate against is affected by this vulnerability. Chisel is often used to provide an entrypoint to a private network, which means services that are gated by Chisel may be affected. Additionally, Chisel is often used for exposing services to the internet. An attacker could MITM requests by connecting to a Chisel server and requesting to forward traffic from a remote port. This issue has been addressed in release version 1.10.0. All users are advised to upgrade. There are no known workarounds for this vulnerability. |
| An unauthenticated remote attacker could potentially disrupt operations by switching between multiple configuration presets via Modbus (TCP). |
| An unauthenticated adjacent attacker could potentially disrupt operations by switching between multiple configuration presets via Modbus (RS485). |