| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue in how XINJE XD5E-24R and XL5E-16T v3.5.3b handles TCP protocol messages allows attackers to cause a Denial of Service (DoS) via a crafted TCP message. |
| qiwen-file v1.4.0 was discovered to contain a SQL injection vulnerability via the component /mapper/NoticeMapper.xml. |
| Integer overflow vulnerability exists in SimplCommerce at commit 230310c8d7a0408569b292c5a805c459d47a1d8f in the shopping cart functionality. The issue lies in the quantity parameter in the CartController's AddToCart method. |
| An improper access control vulnerability exists in SimplCommerce at commit 230310c8d7a0408569b292c5a805c459d47a1d8f, allowing users to submit reviews without verifying if they have purchased the product. |
| mochiMQTT v2.6.3 is vulnerable to Denial of Service (DoS) due to improper resource management. An attacker can exhaust system memory and crash the broker by establishing and maintaining a large number of malicious, long-term publish/subscribe sessions. |
| A vulnerability classified as problematic has been found in Victor Zsviot Camera 8.26.31. This affects an unknown part of the component MQTT Packet Handler. The manipulation leads to denial of service. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-265077 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| An issue in XINJE XL5E-16T V3.7.2a allows attackers to cause a Denial of Service (DoS) via a crafted Modbus message. |
| The XINJE XL5E-16T and XD5E-24R-E programmable logic controllers V3.5.3b-V3.7.2a have a vulnerability in handling Modbus messages. When a TCP connection is established with the above series of controllers within a local area network (LAN), sending a specific Modbus message to the controller can cause the PLC to crash, interrupting the normal operation of the programs running in the PLC. This results in the ERR indicator light turning on and the RUN indicator light turning off. |
| A buffer overflow in the RecvSocketData function of Inovance HCPLC_AM401-CPU1608TPTN 21.38.0.0, HCPLC_AM402-CPU1608TPTN 41.38.0.0, and HCPLC_AM403-CPU1608TN 81.38.0.0 allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted Modbus message. |
| A vulnerability classified as problematic was found in Hipcam Device up to 20240511. This vulnerability affects unknown code of the file /log/wifi.mac of the component MAC Address Handler. The manipulation leads to information disclosure. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-265078 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| Cross Site Scripting vulnerability in Public Knowledge Project PKP Platform OJS/OMP/OPS- before v.3.3.0.16 allows an attacker to execute arbitrary code and escalate privileges via a crafted script |
| The /rest/rights/ REST API endpoint in Becon DATAGerry through 2.2.0 contains an Incorrect Access Control vulnerability. An attacker can remotely access this endpoint without authentication, leading to unauthorized disclosure of sensitive information. |
| An arbitrary file upload vulnerability in the component /main/fileupload.php of AVSCMS v8.2.0 allows attackers to execute arbitrary code via uploading a crafted file. |
| The NetAdmin IAM system (version 4.0.30319) has a Cross Site Scripting (XSS) vulnerability in the /BalloonSave.ashx endpoint, where it is possible to inject a malicious payload into the Content= field. |
| Ruijie NBR800G gateway NBR_RGOS_11.1(6)B4P9 is vulnerable to command execution in /itbox_pi/networksafe.php via the province parameter. |
| AVSCMS v8.2.0 was discovered to contain weak default credentials for the Administrator account. |
| An issue in KIA Seltos vehicle instrument cluster with software and hardware v1.0 allows attackers to cause a Denial of Service (DoS) via ECU reset UDS service. NOTE: this is disputed by the Supplier because the findings came from a potentially unrealistic test environment (an isolated ECU part that was not in a vehicle), and because the ECUReset specification does not allow a manufacturer to require SecurityAccess and Authentication. |
| An issue in KIA Seltos vehicle instrument cluster with software and hardware v1.0 allows attackers to control or disrupt CAN communication between the instrument cluster and CAN bus. NOTE: this is disputed by the Supplier because the findings came from a potentially unrealistic test environment (an isolated ECU part that was not in a vehicle), and because the observed behavior follows the UDS (Unified Diagnostic Services) specification. |
| Incorrect access control in KIA Seltos vehicle instrument cluster with software and hardware v1.0 allows attackers to arbitrarily change odometer readings in the vehicle by targeting the instrument cluster through the unsecured CAN network. NOTE: this is disputed by the supplier because the CAN bus is not externally exposed, and because the packets can only increase the odometer reading (which typically has no value to an adversary). Also, this is disputed by the Supplier because the findings came from a potentially unrealistic test environment (an isolated ECU part that was not in a vehicle), and because the observed behavior follows the UDS (Unified Diagnostic Services) specification. |
| An issue in Beijing Digital China Yunke Information Technology Co.Ltd v.7.2.6.120 allows a remote attacker to execute arbitrary code via the code/function/dpi/web_auth/customizable.php file |