| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper link resolution before file access ('link following') for some Intel(R) Server Configuration Utility software and Intel(R) Server Firmware Update Utility software before version 16.0.12. within Ring 3: User Applications may allow an escalation of privilege. System software adversary with an authenticated user combined with a high complexity attack may enable escalation of privilege. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires active user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts. |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. |
| Insertion of Sensitive Information into Log File vulnerability in Lukman Nakib Debug Log – Manger Tool.This issue affects Debug Log – Manger Tool: from n/a through 1.4.5. |
| SAP Web Dispatcher and Internet Communication Manager allow an attacker with administrative privileges to enable debugging trace mode with a specific parameter value. This exposes unencrypted passwords in the logs, causing a high impact on the confidentiality of the application. There is no impact on integrity or availability. |
| A flaw has been found in SEAT Queue Ticket Kiosk up to 20250827. This affects an unknown part of the component Java RMI Registry Handler. This manipulation causes deserialization. The attack can only be done within the local network. The attack is considered to have high complexity. It is indicated that the exploitability is difficult. The vendor was contacted early about this disclosure but did not respond in any way. |
| Deserialization of Untrusted Data vulnerability in BoldThemes DentiCare denticare allows Object Injection.This issue affects DentiCare: from n/a through < 1.4.3. |
| Reliance on Cookies without Validation and Integrity Checking vulnerability in Talya Informatics Elektraweb allows Session Credential Falsification through Manipulation, Accessing/Intercepting/Modifying HTTP Cookies, Manipulating Opaque Client-based Data Tokens.This issue affects Elektraweb: before v17.0.68. |
| A deserialization of untrusted input vulnerability exists in the cvhDecapsulateCmd functionality of Dell ControlVault3 prior to 5.15.10.14 and ControlVault3 Plus prior to 6.2.26.36. A specially crafted ControlVault response to a command can lead to arbitrary code execution. An attacker can compromise a ControlVault firmware and have it craft a malicious response to trigger this vulnerability. |
| Insertion of Sensitive Information into Log File vulnerability in StylemixThemes Masterstudy LMS Starter.This issue affects Masterstudy LMS Starter: from n/a through 1.1.8. |
| Himmelblau is an interoperability suite for Microsoft Azure Entra ID and Intune. When debugging is enabled for Himmelblau in version 1.0.0, the himmelblaud_tasks service leaks an Intune service access token to the system journal. This short-lived token can be used to detect the host's Intune compliance status, and may permit additional administrative operations for the Intune host device (though the API for these operations is undocumented). This is fixed in version 1.1.0. To workaround this issue, ensure that Himmelblau debugging is disabled. |
| Insecure storage of the ICT MIFARE and DESFire encryption keys in the firmware
binary allows malicious actors to create credentials for any site code and card number that is using the default
ICT encryption.
|
| Gotham Gaia application was found to be exposing multiple unauthenticated endpoints. |
| A link following vulnerability exists in the UnifyScanner component of Armoury Crate. This vulnerability may be triggered by creating a specially crafted junction, potentially leading to local privilege escalation.
For more information, please refer to section 'Security Update for Armoury Crate App' in the ASUS Security Advisory. |
| A vulnerability was found in Smart Office up to 20240405. It has been classified as problematic. Affected is an unknown function of the file Main.aspx. The manipulation of the argument New Password/Confirm Password with the input 1 leads to weak password requirements. It is possible to launch the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. VDB-260574 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| An authenticated user can modify application state data. |
| A flaw was found in Ansible, where sensitive information stored in Ansible Vault files can be exposed in plaintext during the execution of a playbook. This occurs when using tasks such as include_vars to load vaulted variables without setting the no_log: true parameter, resulting in sensitive data being printed in the playbook output or logs. This can lead to the unintentional disclosure of secrets like passwords or API keys, compromising security and potentially allowing unauthorized access or actions. |
| AnyDesk through 8.1.0 on Windows, when Allow Direct Connections is enabled, inadvertently exposes a public IP address within network traffic. The attacker must know the victim's AnyDesk ID. |
| Asio C++ Library before 1.13.0 lacks a fallback error code in the case of SSL_ERROR_SYSCALL with no associated error information from the SSL library being used. |
| A local privilege escalation vulnerability in Sophos Intercept X for Windows with Central Device Encryption 2024.2.0 and older allows writing of arbitrary files. |
| FutureNet MA and IP-K series provided by Century Systems Co., Ltd. put the firmware version and the garbage collection information on the internal web page. With some crafted HTTP request, they can be accessed without authentication. |