Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.
Analysis and contextual insights are available on OpenCVE Cloud.
Remediation
No vendor fix or workaround currently provided.
Additional remediation guidance may be available on OpenCVE Cloud.
Tracking
Sign in to view the affected projects.
Advisories
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2020-28706 | A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges. |
References
History
No history.
Subscriptions
Siemens
Subscribe
Opcenter Execution Discrete
Subscribe
Opcenter Execution Foundation
Subscribe
Opcenter Execution Process
Subscribe
Opcenter Intelligence
Subscribe
Opcenter Quality
Subscribe
Opcenter Rd\&l
Subscribe
Simatic Notifier Server
Subscribe
Simatic Pcs Neo
Subscribe
Simatic Step 7
Subscribe
Simocode Es
Subscribe
Soft Starter Es
Subscribe
Status: PUBLISHED
Assigner: siemens
Published:
Updated: 2024-08-04T09:33:19.617Z
Reserved: 2020-01-21T00:00:00.000Z
Link: CVE-2020-7581
No data.
Status : Modified
Published: 2020-07-14T14:15:18.587
Modified: 2024-11-21T05:37:24.977
Link: CVE-2020-7581
No data.
OpenCVE Enrichment
No data.
Weaknesses
EUVD