This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Analysis and contextual insights are available on OpenCVE Cloud.
No vendor fix or workaround currently provided.
Additional remediation guidance may be available on OpenCVE Cloud.
Tracking
Sign in to view the affected projects.
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2024-40401 | Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
Thu, 09 Jan 2025 15:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
cvssV3_1
|
Thu, 09 Jan 2025 08:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | |
| Title | When uploading new firmware, a shell script inside a firmware file is executed during its processing. This can be used to craft a custom firmware file with a custom script with arbitrary code, which will then be executed on the charging station. | |
| Weaknesses | CWE-434 CWE-78 |
|
| References |
| |
| Metrics |
cvssV4_0
|
Subscriptions
No data.
Status: PUBLISHED
Assigner: DIVD
Published:
Updated: 2025-03-11T13:07:14.017Z
Reserved: 2024-08-14T09:27:41.769Z
Link: CVE-2024-43657
Updated: 2025-01-09T14:44:04.718Z
Status : Deferred
Published: 2025-01-09T08:15:28.680
Modified: 2026-04-15T00:35:42.020
Link: CVE-2024-43657
No data.
OpenCVE Enrichment
No data.
EUVD