Description
CWE-798 Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to sensitive device information when an unauthenticated attacker is able to interrogate the SNMP port.
Published: 2026-04-14
Score: 6.9 Medium
EPSS: < 1% Very Low
KEV: No
Impact: Unauthorized access to sensitive device information
Action: Apply Patch
AI Analysis

Analysis and contextual insights are available on OpenCVE Cloud.

Remediation

No vendor fix or workaround currently provided.

Additional remediation guidance may be available on OpenCVE Cloud.

Tracking

Sign in to view the affected projects.

Advisories

No advisories yet.

History

Wed, 15 Apr 2026 21:15:00 +0000

Type Values Removed Values Added
First Time appeared Schneider-electric
Schneider-electric easergy P14x
Schneider-electric easergy P24x
Schneider-electric easergy P341
Schneider-electric easergy P342
Schneider-electric easergy P343
Schneider-electric easergy P344
Schneider-electric easergy P345
Schneider-electric easergy P442
Schneider-electric easergy P443
Schneider-electric easergy P444
Schneider-electric easergy P445
Schneider-electric easergy P446
Schneider-electric easergy P543
Schneider-electric easergy P544
Schneider-electric easergy P545
Schneider-electric easergy P546
Schneider-electric easergy P642
Schneider-electric easergy P643
Schneider-electric easergy P645
Schneider-electric easergy P741
Schneider-electric easergy P742
Schneider-electric easergy P743
Schneider-electric easergy P746
Schneider-electric easergy P841
Schneider-electric easergy P849
Vendors & Products Schneider-electric
Schneider-electric easergy P14x
Schneider-electric easergy P24x
Schneider-electric easergy P341
Schneider-electric easergy P342
Schneider-electric easergy P343
Schneider-electric easergy P344
Schneider-electric easergy P345
Schneider-electric easergy P442
Schneider-electric easergy P443
Schneider-electric easergy P444
Schneider-electric easergy P445
Schneider-electric easergy P446
Schneider-electric easergy P543
Schneider-electric easergy P544
Schneider-electric easergy P545
Schneider-electric easergy P546
Schneider-electric easergy P642
Schneider-electric easergy P643
Schneider-electric easergy P645
Schneider-electric easergy P741
Schneider-electric easergy P742
Schneider-electric easergy P743
Schneider-electric easergy P746
Schneider-electric easergy P841
Schneider-electric easergy P849

Tue, 14 Apr 2026 19:15:00 +0000

Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'yes', 'Exploitation': 'none', 'Technical Impact': 'partial'}, 'version': '2.0.3'}


Tue, 14 Apr 2026 16:45:00 +0000

Type Values Removed Values Added
Title Hard‑coded SNMP Credentials Enable Unauthorized Device Access

Tue, 14 Apr 2026 15:45:00 +0000

Type Values Removed Values Added
Description CWE-798 Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to sensitive device information when an unauthenticated attacker is able to interrogate the SNMP port.
Weaknesses CWE-798
References
Metrics cvssV4_0

{'score': 6.9, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N'}


Subscriptions

Schneider-electric Easergy P14x Easergy P24x Easergy P341 Easergy P342 Easergy P343 Easergy P344 Easergy P345 Easergy P442 Easergy P443 Easergy P444 Easergy P445 Easergy P446 Easergy P543 Easergy P544 Easergy P545 Easergy P546 Easergy P642 Easergy P643 Easergy P645 Easergy P741 Easergy P742 Easergy P743 Easergy P746 Easergy P841 Easergy P849
cve-icon MITRE

Status: PUBLISHED

Assigner: schneider

Published:

Updated: 2026-04-14T18:16:06.726Z

Reserved: 2026-03-25T14:13:10.490Z

Link: CVE-2026-4832

cve-icon Vulnrichment

Updated: 2026-04-14T18:15:58.207Z

cve-icon NVD

Status : Awaiting Analysis

Published: 2026-04-14T16:16:48.167

Modified: 2026-04-17T15:11:35.840

Link: CVE-2026-4832

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

Updated: 2026-04-15T21:03:02Z

Weaknesses