Export limit exceeded: 351254 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 351254 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (351254 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-35291 | 2026-04-15 | 6.1 Medium | ||
| Cross-site scripting vulnerability exists in Splunk Config Explorer versions prior to 1.7.16. If this vulnerability is exploited, an arbitrary script may be executed on the web browser of the user who is using the product. | ||||
| CVE-2024-35292 | 1 Siemens | 10 Simatic S7-200 Smart Cpu Cr40, Simatic S7-200 Smart Cpu Cr60, Simatic S7-200 Smart Cpu Sr20 and 7 more | 2026-04-15 | 8.2 High |
| A vulnerability has been identified in SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1) (All versions). Affected devices are using a predictable IP ID sequence number. This leaves the system susceptible to a family of attacks which rely on the use of predictable IP ID sequence numbers as their base method of attack and eventually could allow an attacker to create a denial of service condition. | ||||
| CVE-2024-35293 | 2026-04-15 | 9.1 Critical | ||
| An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS. | ||||
| CVE-2024-35294 | 2026-04-15 | 6.5 Medium | ||
| An unauthenticated remote attacker may use the devices traffic capture without authentication to grab plaintext administrative credentials. | ||||
| CVE-2024-35295 | 2026-04-15 | 6.1 Medium | ||
| A vulnerability has been identified in Perfect Harmony GH180 (All versions >= V8.0 < V8.3.3 with NXGPro+ controller manufactured between April 2020 to April 2025). The maintenance connection of affected devices fails to protect access to the device's control unit configuration. This could allow an attacker with physical access to the maintenance connection's door port to perform arbitrary configuration changes. | ||||
| CVE-2024-35297 | 1 Wordpress | 1 Wordpress | 2026-04-15 | 4.7 Medium |
| Cross-site scripting vulnerability exists in WP Booking versions prior to 2.4.5. If this vulnerability is exploited, an arbitrary script may be executed on the web browser of the user who is accessing the web site using the product. | ||||
| CVE-2024-35298 | 2026-04-15 | 4.3 Medium | ||
| Improper authorization in handler for custom URL scheme issue in 'ZOZOTOWN' App for Android versions prior to 7.39.6 allows an attacker to lead a user to access an arbitrary website via another application installed on the user's device. As a result, the user may become a victim of a phishing attack. | ||||
| CVE-2024-35303 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2026-04-15 | 7.8 High |
| A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0012), Tecnomatix Plant Simulation V2404 (All versions < V2404.0001). The affected applications contain a type confusion vulnerability while parsing specially crafted MODEL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22958) | ||||
| CVE-2024-35311 | 2026-04-15 | 3.3 Low | ||
| Yubico YubiKey 5 Series before 5.7.0, Security Key Series before 5.7.0, YubiKey Bio Series before 5.6.4, and YubiKey 5 FIPS before 5.7.2 have Incorrect Access Control. | ||||
| CVE-2024-35312 | 2026-04-15 | 6.2 Medium | ||
| In Tor Arti before 1.2.3, STUB circuits incorrectly have a length of 2 (with lite vanguards), aka TROVE-2024-003. | ||||
| CVE-2024-35313 | 2026-04-15 | 7.3 High | ||
| In Tor Arti before 1.2.3, circuits sometimes incorrectly have a length of 3 (with full vanguards), aka TROVE-2024-004. | ||||
| CVE-2024-35333 | 2026-04-15 | 8.4 High | ||
| A stack-buffer-overflow vulnerability exists in the read_charset_decl function of html2xhtml 1.3. This vulnerability occurs due to improper bounds checking when copying data into a fixed-size stack buffer. An attacker can exploit this vulnerability by providing a specially crafted input to the vulnerable function, causing a buffer overflow and potentially leading to arbitrary code execution, denial of service, or data corruption. | ||||
| CVE-2024-35341 | 2026-04-15 | 7.5 High | ||
| Certain Anpviz products allow unauthenticated users to download the running configuration of the device via a HTTP GET request to /ConfigFile.ini or /config.xml URIs. This configuration file contains usernames and encrypted passwords (encrypted with a hardcoded key common to all devices). This affects IPC-D250, IPC-D260, IPC-B850, IPC-D850, IPC-D350, IPC-D3150, IPC-D4250, IPC-D380, IPC-D880, IPC-D280, IPC-D3180, MC800N, YM500L, YM800N_N2, YMF50B, YM800SV2, YM500L8, and YM200E10 firmware v3.2.2.2 and lower and possibly more vendors/models of IP camera. | ||||
| CVE-2024-35342 | 2026-04-15 | 4.6 Medium | ||
| Certain Anpviz products allow unauthenticated users to modify or disable camera related settings such as microphone volume, speaker volume, LED lighting, NTP, motion detection, etc. This affects IPC-D250, IPC-D260, IPC-B850, IPC-D850, IPC-D350, IPC-D3150, IPC-D4250, IPC-D380, IPC-D880, IPC-D280, IPC-D3180, MC800N, YM500L, YM800N_N2, YMF50B, YM800SV2, YM500L8, and YM200E10 firmware v3.2.2.2 and lower and possibly more vendors/models of IP camera. | ||||
| CVE-2024-35343 | 1 Anpviz | 17 Ipc-b850 Firmware, Ipc-d250 Firmware, Ipc-d260 Firmware and 14 more | 2026-04-15 | 9.8 Critical |
| Certain Anpviz products allow unauthenticated users to download arbitrary files from the device's filesystem via a HTTP GET request to the /playback/ URI. This affects IPC-D250, IPC-D260, IPC-B850, IPC-D850, IPC-D350, IPC-D3150, IPC-D4250, IPC-D380, IPC-D880, IPC-D280, IPC-D3180, MC800N, YM500L, YM800N_N2, YMF50B, YM800SV2, YM500L8, and YM200E10 (IP Cameras) firmware v3.2.2.2 and lower and possibly more vendors/models of IP camera. | ||||
| CVE-2024-35344 | 2026-04-15 | 9.9 Critical | ||
| Certain Anpviz products contain a hardcoded cryptographic key stored in the firmware of the device. This affects IPC-D250, IPC-D260, IPC-B850, IPC-D850, IPC-D350, IPC-D3150, IPC-D4250, IPC-D380, IPC-D880, IPC-D280, IPC-D3180, MC800N, YM500L, YM800N_N2, YMF50B, YM800SV2, YM500L8, and YM200E10 firmware v3.2.2.2 and lower and possibly more vendors/models of IP camera. | ||||
| CVE-2024-35361 | 1 Mtab | 1 Bookmark | 2026-04-15 | 9.8 Critical |
| MTab Bookmark v1.9.5 has an SQL injection vulnerability in /LinkStore/getIcon. An attacker can execute arbitrary SQL statements through this vulnerability without requiring any user rights. | ||||
| CVE-2024-35371 | 1 Ant-media | 1 Ant-media-server | 2026-04-15 | 7.5 High |
| Ant-Media-Serverv2.8.2 is affected by Improper Output Neutralization for Logs. The vulnerability stems from insufficient input sanitization in the logging mechanism. Without proper filtering or validation, user-controllable data, such as identifiers or other sensitive information, can be included in log entries without restrictions. | ||||
| CVE-2024-3546 | 1 Webtoffee | 1 Backup And Migration | 2026-04-15 | 4.3 Medium |
| The WordPress Backup & Migration plugin for WordPress is vulnerable to unauthorized access of data due to a missing capability check on the wp_mgdp_populate_popup function in all versions up to, and including, 1.4.8. This makes it possible for authenticated attackers, with subscriber access or above, to invoke this function and access log files maintained by the plugin. Additionally, the file name is user-provided and not properly sanitized, which allows attackers to read arbitrary log files on the file system. | ||||
| CVE-2024-35474 | 2026-04-15 | 6.5 Medium | ||
| A Directory Traversal vulnerability in iceice666 ResourcePack Server before v1.0.8 allows a remote attacker to disclose files on the server, via setPath in ResourcePackFileServer.kt. | ||||